THE ULTIMATE PACKAGED VFD SOLUTION

HazLo Drive: Hazardous Location VFD

  • UL listed, Class I Division 2 VFD
  • 20 - 100 HP @ 480 VAC (575 VAC 3Ø input option)
  • NEMA Type 4X / IP66 enclosure
  • Multiple communication protocols supported
  • 316 Stainless Steel or Carbon Steel (painted safety yellow)
  • In stock with fast shipping

Product Overview

Overview

The HazLo Drive is a VFD rated to UL Class I Division 2 hazloc environments. Available in 20-100 HP 480 VAC or 575 VAC 3Ø inputs, the HazLo is a wall mountable NEMA Type 4X (IP66) enclosure which is suitable for indoor or outdoor use.

Design

Our patented cUL listed design, packages a Vacon vfd in a NEMA 4X rated enclosure for Class 1 Div 2 environments. The HazLo can be installed near the application process reducing costs associated with long motor lead lengths. The HazLo is able to work outside without additionl protection and includes an 'Arctic Mode' allowing it to operate down to as low as -10ºc.

Features

  • 10-100 HP, 480 VAC or 575 VAC 3Ø input
  • Built-in braking resistor for high inertia loads
  • 25 step sequencer - PLC like capabilities, programmable macro’s
    • Improved functionality is closer to traditional PLC than available with current X4 designs
    • New loop and branch capabilities available
  • Real time clock function
    • Control operations based on time-of-day (TOD) and day-of-the-week
    • Fault information - real time data is stored with all faults
    • Signals an event via text on the display or contact closure, independent of drive operation
    • Keeper function - logs time-based data from external or internal signals
  • USB port for multi-drive programming with the parameter save / recall feature
    • Save parameter set to USB enabling upload to another drive
    • Store data and view with Microsoft Excel
    • Ability to define custom file name (numbers or text)
    • Easy firmware upgrades
  • No temperature de-rating required up to 50ºc
  • Immediate startup, no purge delay or air conditioning required

Options

  • Communication boards for Ethernet IP, DeviceNet, ModBus TCP/IP or ProfiBUS
    • The ability to accept option boards enhances the Vacon X5’s application flexibility. All options include five (5) channels of 115 VAC control

Certifications

UL Listed, Class 1, Division 2 Groups A, B, C & D at temp T3C

Markets

  • Oil & Gas
  • Petrochemical
  • Refineries
  • Pharmaceutical
  • Water & Waste Water
  • Chemical
  • Distilleries
  • Agricultural
  • Paint Booths

More Info

For more information please contact us at 281.516.3130 or email info@saidrives.com

saidrive hazlo ul class1 div2 front yellow 190saidrive hazlo ul class1 div2 front stainless 190madeinusa w80

Specifications

CARBON STEEL - SAFETY YELLOW      
Motor Shaft Power and current (480V) Frame Size Dimensions
W x H x D (mm)
W x H x D (in)
Weight (kg)
Weight (lbs)
High Overload (150%) Low Overload (120%)
Part Number HP kW Amps HP kW Amps
X5C40400X 30 HP 22 40 40 HP 30 52 F3 286 x 513 x 314
11.19 x 20.19 x 11.73
22.68
50
X5C40500X 40 HP 30 52 50 HP 37 65
X5C40600X 50 HP 37 65 60 HP 45 77 F4 326 x 745 x 351
12.84 x 29.35 x 13.8
43.1
95
X5C40750X 60 HP 45 77 75 HP 55 96
X5C401000X 75 HP 55 96 100 HP 75 124

 

316 STAINLESS STEEL      
Motor Shaft Power and current (480V) Frame Size Dimensions W x H x D (mm) W x H x D (in) Weight (kg) Weight (lbs)
High Overload (150%) Low Overload (120%)
Part Number HP kW Amps HP kW Amps
X5C40400Y 30 22 40 40 30 52 F3

286 x 513 x 314
11.19 x 20.19 x 11.73

22.68 Kg
50 lbs

X5C40500Y 40 30 52 50 37 65
X5C40600Y 50 37 65 60 45 77 F4

326 x 745 x 351
12.84 x 29.35 x 13.8

43.1 Kg
95 lbs
X5C40750Y 60 45 77 75 55 96
X5C401000Y 75 55 96 100 75 124

 

Environmental       Operating Temperature -10°C to +40°C (14°F to 104°F)
Storage Temperature -20°C to +65°C (-4°F to 149°F)
Humidity 0% to 95% non-condensing
Altitude 1,000m (3,300 ft) without derating
Maximum vibration Per EN50178: Frame Size 1 - 5G
Acoustic Noise 80 dba sound power at 1m (3ft)
Agency approvals UL, cUL, CE
Electrical        Input Voltage 380-460 or 575 Vac, 3 phase, +/- 15%
Line Frequency 50 / 60 Hz +/-2 Hz
Source kVA (maximum) 10 times the unit rated kVA (65kA maximum)
DC bus voltage for:
Overvoltage trip
Dynamic brake activation
Normal under voltage (UV) trip
460 Vac Models
814 Vdc
776 Vdc
397 Vdc
Control system V/Hz or Sensorless Vector Control (SVC)
Carrier frequency = 1 to 16 kHz programmable
Output voltage 0 to 100% of line voltage, 3 phase
Overload capacity 120% of rated RMS current for 60 seconds (Normal Duty rating)
150% of rated RMS current for 60 seconds (Heavy Duty Rating)
Frequency output Range: 0.1 - 400Hz; Stability: 0.1Hz, 0.1% analog over 24 hours +/- 10°C

 

Control Features         DC holding/injection braking At start, stop, by frequency with adjustable current level and time and time or continuous DC injection by digital input.
Current limit Four-quadrant adjustable from 5 to 150%
Speed ramps Primary and alternate adjustable from 0.1 to 3200.0 seconds
Voltage boost Adjustable fixed boost or adjustable auto boost
Voltage characteristic V/Hz - Linear, pump, fan or 2-piece linear; Sensorless Vector
Timed Overload Adjustable inverse time trip (shear pin, 30 sec, 60 sec, 5 minutes) for standard or inverter-duty motors
Protective features Overcurrent, Overvoltage fault, ground fault, short circuit, dynamic Brake overload, drive temperature, power wiring fault. Drive-timed overload, input voltage quality, overvoltage ride through
Program Sequence Controller 25-step, PLC-type functionality that can control speed, direction and ramps based on time, analog input, digital input, or pulse input. Conditional branching, addressable outputs and real time operations possible.
PI and PID Feedback Process control available with the use of a customer supplied transducer, either 0-10Vdc, 4-20mA or optical encoder input to the drive. Includes an optional sleep mode, activated when the loop is satisfied.

Downloads

Downloads for HazLo Drive

 

Line Card

Brochure

AC Drive User Manual (Vacon X5)

VFD Selection Guide

More downloads available in the download section of the website Support Downloads

Configure and Buy

Use the drop-down selections to customize your XP Drive, then click 'add to cart' to start the checkout process.

Instructions:

  1. Select Voltage
  2. Select Variable Torque Profile
  3. Select HP
  4. Select Enclosure type

To learn more about the terms and relationships between normal duty, variable torque, low overload, heady duty, constant torque and high overload - click here

When you are ready to place your order, click on the 'checkout' link below or the 'view cart' link across the top of the page.